Military Fluids
ASTM D3487-00 FED SPEC# VV-I-530
| Radco Industries, Inc. |
 |
| PO Box 305 |
 |
| LaFox, IL 60147 |
Manufacturing Location: LaFox IL |
Telephone: (800) 854-4865 Fax: (630) 232-7968 |
DESCRIPTION |
REQUIREMENT |
TYP. RESULT |
TEST METHOD |
Kinematic Viscosity,
Centistokes
|
 |
 |
 |
| @ 0 °C, |
76 cSt max |
67.1cSt |
ASTM-D455 |
| @ 100 °C, |
3.0 cSt max |
2.31cSt |
ASTM-D455 |
| @ 40 °C |
12 cSt max |
9.3 cSt |
ASTM-D455 |
Pour Point
Color
Interfacial Tension
Analine Point °C
|
-40°F max
0.5 max
>39.99 dynes/cm
76°C max |
-52 °F
<0.5
49
74 |
ASTM-D97
ASTM-D1500
ASTM-D971
ASTM-D611 |
Visual Exam
Flash Point, minimum
|
clear and bright
>294.99 °F |
pass
305 °F / 150 °C |
ASTM-D1524
ASTM-D92 |
| Density @15°C/15°C |
0.91 max |
0.8930 |
ASTM-D1298 |
| Total acid number, max. |
0.3 mg KOH/g |
0.0 mg KOH/gm |
ASTM-D974 |
| Water content, Karl Fisher |
35 ppm max |
8 ppm |
ASTM-D1533 |
Dielectric Strength
VDE Electrodes
Impulse Strength
Dissipation (Power) Factor
@ 25 °C
@ 100 °C
|
>29.9 KVA
>34.9 KVA
>145 KVA
0.05% max
0.3% max |
42 KVA
32 KVA
226 KVA
0.009%
0.06% |
ASTM-D877
ASTM-D1816
ASTM-D3300
ASTM-D924
ASTM-D924 |
CHARACTERISTIC |
REQUIREMENT |
RESULT |
TEST METHOD |
| Oxidation stability, 72h |
 |
 |
 |
| % sludge, max (by mass) |
0.15 max |
0.08 |
ASTM-D2440 |
| TAN, max mg KOH/g |
0.5 max |
0.31 |
ASTM-D2440 |
| Oxidation stability, 164h |
 |
 |
 |
| % sludge, max (by mass) |
0.3 max |
0.1 |
ASTM-D2440 |
| TAN, max mg KOH/g |
0.6 max |
0.30 |
ASTM-D2440 |
| Oxidation Stability (RBOT) |
NA |
|
ASTM-D2112 |
| Oxidation inhibitor content |
0.08 % max |
none |
ASTM-D2668 |
| Corrosive sulfur |
non-corrosive |
pass |
ASTM-D1275 |
| PCB Content
|
non-detectable |
pass |
ASTM-D4059 |
| Pounds per US Gallon |
none |
7.4 A |
STM-D4052 |
| API gravity @ 60°F |
none |
26.96 |
ASTM-D4052 |
| Operations Approval |
none |
approved |
 |
XCELTHERM® Electrical Insulation Oil (Type I) meets military standard specifications for electrical oil applications. XCELTHERM® EIO-I has high electrical resistance and is both thermally and oxidatively stable. XCELTHERM® EIO-I is intended for use in most common electrical insulating oil applications where normal oxidation resistance is required. It is compatible with other electrical insulating oils, including Shell Diala® A
CALL FOR AN MSDS!
Worldwide - 630.232.7966
US - 800.854.4865
|  |